ZJSHUYI Classic case of inverter maintenance failure.www.shuyitop.com; ...
Foreword: Inverter repairers must keep in mind that the inverter module and the drive circuit are strongly related to failures. When the inverter module bursts and damages, the drive circuit is bound to be damaged by impact. The damage of the inverter module may also be caused by the failure of the drive circuit. Therefore, whether it is a failure of the drive circuit or the inverter output circuit, it must be The inverter output circuit and the drive circuit are thoroughly inspected together. The power-on test of the main circuit must be carried out under the premise that the drive circuit is normal and can output six excitation pulses normally. Inverter power failure A 132KW inverter has a black screen fault. Part of the wire drawing machine stopped in the wire drawing workshop, and restarted production after half a month. As a result, the inverter went black after being powered on. It was judged that the switching power supply was faulty on the spot. The inverter was removed, and th...