博文

目前显示的是 九月, 2022的博文

ZJSHUYI Count the electrical packaging and delivery.www.shuyitop.com; #...

图片
Zhejiang Digital One Electric Co., Ltd. is led by an experienced R & D team and is equipped with rich development equipment. Innovation and perfectionism are our creed. Guided by advanced design theory and methods, we can provide various high -cost products, including inverter, soft starter, switch, relay, interchange contactor, circuit breaker, circuit breaker, Our cooperation with each customer starts with some samples. From sample orders to trial orders to batch production, our service purpose is to do the best for each order. Provide all the information that customers want, including product pictures, packaging pictures, packing orders, invoices. Thanks to customers for their recognition and constant orders, we will have far -reaching and long -term cooperation. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #softstarter #motorsoftstar #softstarters #softstartechnology #solidstatesoftstarter #functionsmartsoftstarter #ZJSHUYI #intelligentmotorso

ZJSHUYI What occasions are soft starters suitable for?www.shuyitop.com; ...

图片
According to the function of the soft starter, it is suitable for the following occasions: 1. Machinery for short-term repetitive work. This refers to machinery with long-term no-load (light load less than 35%), short-term heavy load, high no-load rate, or machinery with low load duration rate, such as cranes, belt conveyors, metal material calenders, lathes, punches , planer, shearing machine, etc. 2. Work machinery with functions such as sudden jump, smooth acceleration, smooth deceleration, quick stop, low-speed braking, and accurate positioning is required. 3. Motors with long-term high speed and short-term low speed. When the load rate is lower than 35%, the soft starter has better energy saving effect. 4. Where there are multiple motors and these motors do not need to be started at the same time. 5. The occasions where the motor is not allowed to shut down instantly. Such as high-rise buildings and other pump systems, if the instantaneous stop, will produce a huge "wat

ZJSHUYI How the time relay works.www.shuyitop.com;#timerelay #relay

图片
A time relay is a relay that is generated by the output circuit within a specified and accurate time after adding or removing the input action signal. It is used to connect or cut off high-voltage and high-current circuits, and is used in low-current circuits. The time relay is a very important part in the electrical control system. In many control systems, time relays are used to achieve delay control. Time relay is an automatic control electrical appliance that uses the principle of electromagnetic or mechanical action to delay the closing or opening of contacts. It is characterized by a delay from the signal obtained by the attracting coil to the contact action. Motor startup process. Web: www.shuyitop.com; Tel/Fax: 0086-577-62840011 Wechat/WhatsApp: 008613355775769 #ZJSHUYI #Chinashuyi #shuyitop #TemperatureController #timerelay #relay

ZJSHUYI Classic case of inverter maintenance failure.www.shuyitop.com; ...

图片
Foreword: Inverter repairers must keep in mind that the inverter module and the drive circuit are strongly related to failures. When the inverter module bursts and damages, the drive circuit is bound to be damaged by impact. The damage of the inverter module may also be caused by the failure of the drive circuit. Therefore, whether it is a failure of the drive circuit or the inverter output circuit, it must be The inverter output circuit and the drive circuit are thoroughly inspected together. The power-on test of the main circuit must be carried out under the premise that the drive circuit is normal and can output six excitation pulses normally. Inverter power failure A 132KW inverter has a black screen fault. Part of the wire drawing machine stopped in the wire drawing workshop, and restarted production after half a month. As a result, the inverter went black after being powered on. It was judged that the switching power supply was faulty on the spot. The inverter was removed, and th

ZJSHUYI Soft starter MCC control cabinet.www.shuyitop.com;#softstarter

图片
MCC is shorted for Motor Control Center. Soft starter MCC control cabinet consists of the following components: (1) input circuit breaker, (2) Soft starter (including electronic control circuit and three phase thyristor), (3) soft starter bypass contactor, (4) secondary-side control circuit (for manual start, remote start, soft start and direct start functions selection and operation), and voltage, current display, fault, running and working status indicators.We can achieve various complex functions with combinations of soft starter MCC control cabinet. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #softstarter #motorsoftstar #softstarters #softstartechnology #solidstatesoftstarter #functionsmartsoftstarter #ZJSHUYI #intelligentmotorsoftstarter #chinashuyi #Softstartercabinet

ZJSHUYI The role of solid state relays.www.shuyitop.com;#SSR #solidstat...

图片
Solid-state relay is a new type of non-contact switching device composed of solid-state electronic components. It uses the switching characteristics of electronic components (such as switching transistors, triacs and other semiconductor devices) to achieve non-contact and non-spark switching. And the purpose of disconnecting the circuit, so it is also called "non-contact switch". Solid state relay is a four-terminal active device, two terminals are input control terminals, and the other two terminals are output controlled terminals. It has both amplifying and driving functions and isolation functions, which is very suitable for driving high-power switching actuators , Compared with electromagnetic relays, it has higher reliability, and has no contacts, long life, fast speed, and little interference to the outside world, and has been widely used. Web: www.shuyitop.com; Tel/Fax: 0086-577-62840011 Wechat/WhatsApp: 008613355775769 Zhejiang SHUYI Electric Co., LTD, Focus on switch

ZJSHUYI Low-voltage inverter application field.www.shuyitop.com; #freque...

图片
In the field of low-voltage inverter applications, low-voltage inverters have been applied in all walks of life in my country, such as metallurgy, chemical industry, papermaking, machinery and other industries. More specific applications, small applications such as blowers, conveyors, feeders, mixers, grinders, pulverizers, paper cutters, calenders, extruders, valves, compressors, cooling pedals, plastics Machinery, elevators, various textile industries, etc.; large-scale application fields such as paper machines in paper mills, injection molding machines in mold factories, rolling mills in metallurgical plants, and fans, pumps, cranes, oil pipelines, etc. in chemical industries. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #VFD #frequencyconverter #acdrive #frequencyinverter #inverter #frequencydrive #acvfdvariablefrequencydrive #vfddriveprice #shuyitop #converter #inverters #vfds #vfdmarket #ZJSHUYI #Chinashuyi

ZJSHUYI Can a high-power soft starter bring a small motor?www.shuyitop.c...

图片
If the high-power soft starter is used to debug the cabinet, it is best to have a light bulb. . For example, 200KW with a small motor can be started very quickly, because the rated current of the small motor is small, and the high-power soft starter cannot detect the running current, it will report a phase loss fault. . If debugging, bring a light bulb and look at the three-phase trigger to measure the quality of the soft start or control loop. . . When the high-power soft starter runs with a small motor on site, pay attention to the setting of the protection parameters of the soft starter, otherwise various protection functions may fail. For example, if it is a water pump with low power, a 90KW soft start with a 90KW motor can be used. . For heavy loads, such as fans, belt conveyors, etc., it is recommended that you choose a soft start of 115KW. The 90KW soft starter is equipped with a 75KW motor. After all, the big horse-drawn trolley is relatively stable and reliable. However, high-

ZJSHUYI Solid state relays have been widely used in life.www.shuyitop.co...

图片
Solid state relays have been widely used in computer peripheral interface equipment, constant temperature systems, temperature regulation, electric furnace heating control, motor control, numerical control machinery, remote control systems, industrial automation devices; signal lights, dimming, flashers, lighting stage lighting control systems; instruments; Instruments, medical equipment, copiers, automatic washing machines; automatic fire protection, security systems, and power capacitor switches as power factor compensation for power grids, etc. In addition, they are widely used in chemical, coal mines and other occasions that require explosion-proof, moisture-proof and corrosion-proof . Web: www.shuyitop.com; Tel/Fax: 0086-577-62840011 Wechat/WhatsApp: 008613355775769 #SSR #solidstaterelay #ZJSHUYI #Chinashuyi #shuyitop

ZJSHUYI Test run confirmation and parameter setting.www.shuyitop.com; #s...

图片
Test run confirmation and parameter setting 1. Confirm that the use environment and input power meet the requirements of product technical performance and design. 2. Confirm that the wiring is correct, especially the input wiring of the power supply. 3. Confirm that there is no short circuit or short circuit to ground between terminals and live parts. 4. Confirm that all terminals, connectors, and connecting bolts are fastened and there is no looseness. 5. After the test run is checked and confirmed, according to the technical requirements of the electrical equipment, set and debug the function operation parameters and fault protection parameters according to the user manual. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #softstarter #motorsoftstar #softstarters #softstartechnology #softstartermarket #softstarterprice #ac powersoftstarterwithbuilt-inbypass #builtinbypasssoftstarter #singlephasemotorsoftstarter #ZJSHUYI #Chinashuyi

ZJSHUYI The working principle of the AC contactor.www.shuyitop.com; #fre...

图片
The working principle of the AC contactor is to use the electromagnetic force to cooperate with the spring force to realize the connection and disconnection of the contacts. The AC contactor has two working states: de-energized state (release state) and electrified state (action state). When the attraction coil is energized, the static iron core generates electromagnetic attraction, the armature is pulled in, and the connecting rod connected to the armature drives the contact to move, so that the normally closed contact breaker is in an electrified state; when the attraction coil is de-energized, the The electromagnetic attraction disappears, the armature is re-opened, the normally open contacts are closed and released under the action of the position spring, all the contacts are reset accordingly, and the contactor is in a power-off state. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #softstarter #motorsoftstar #softstarters #VFD #contactor #ACcont

ZJSHUYI The reason why the soft start of the motor cannot protect. www.s...

图片
If the soft start of the motor cannot protect, it means that your parameter setting is unreasonable, or even the function setting is wrong. 1. Soft start is used to start the motor to prevent too much starting current from impacting the power grid when starting. The soft-start device is only active during the start-up process. 2. Motor burning prevention is the responsibility of the motor's overload protection device. The simplest fuse is generally a thermal resistance. But the general soft starter can be achieved. 3. The motor still burns, indicating that your circuit design is unreasonable. The configuration of the device is not reasonable. Or not consider overload protection at all. I thought that as long as it was installed, it would provide overload protection. In fact, it needs to be debugged first. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #softstarter #motorsoftstar #softstarters #softstartechnology #softstartermarket #softstarterprice #

ZJSHUYI Customized soft start fire control cabinet.www.shuyitop.com; #so...

图片
Fire control cabinet (automatic control cabinet) is a kind of industrial control equipment that is more common in our lives, such as corridors, underground parking lots, gas stations and other public places. However, many friends do not know what it is called or what it is used for. The following ZJSHUI editor will explain what is a fire control cabinet. The fire control cabinet is a safe fire fighting tool provided by the pump factory. Its main purpose is to protect the pump motor from overvoltage, short circuit and overload. And also has a sound and light alarm function. It plays an important role in extinguishing fire and is also a fire safety device that can help control the fire after a fire occurs. Zhejiang Shuyi Electric Co., Ltd. can customize the soft-start fire control cabinet you need www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #softstarter #motorsoftstar #softstarters #softstartechnology #solidstatesoftstarter #Softstartcontrolcabinet #ZJS

ZJSHUYI Difference between soft starter and frequency converter.www.shuy...

图片
Soft starter is actually a motor control device with motor #softstart , soft stop, light load energy saving and various protection functions. It is mainly a three-phase parallel thyristor and its electronic control circuit connected in series between the power supply and the controlled motor. By controlling the conduction angle of the three-phase parallel thyristor, the input voltage of the controlled motor can be changed according to different requirements, and various functions can be realized. The #inverter is mainly used where speed regulation is required. Its output not only changes the voltage but also changes the frequency at the same time; the soft starter is actually a voltage regulator. When the motor is started, the output only changes the voltage and does not change the frequency. The frequency converter manufacturer emphasizes that the frequency converter has all the functions of the soft starter, but its price is more expensive than that of the soft starter, and the stru

ZJSHUYI Can the DC-AC base of the intermediate relay be universal?www.sh...

图片
Whether the intermediate relay is DC or AC, the working principle is the same, the only difference is the voltage level. The working principle of the intermediate relay is the same as that of the relay and the AC contactor. When the contactor coil is energized, the coil current will generate a magnetic field, and the generated magnetic field will cause the static iron core to generate electromagnetic attraction to attract the moving iron core and drive the AC contactor point action, normally closed contact is disconnected, normally open contact is closed, the two are linked. When the coil is powered off, the electromagnetic attraction disappears, and the armature is released under the action of the release spring, so that the contacts are restored, the normally open contacts are disconnected, and the normally closed contacts are closed. Web: www.shuyitop.com; Tel/Fax: 0086-577-62840011 Wechat/WhatsApp: 008613355775769 #ZJSHUYI #Chinashuyi #shuyitop #relay #ACrelay #DCrelay #Intermed

ZJSHUYI Function of each key on the inverter panel. www.shuyitop.com; #f...

图片
1: PRG, function: enter the parameter setting interface, and switch between different series of parameters. 2: ENTER. Parameter confirmation. After we adjust the value of the parameter to be adjusted, we need to press this key to confirm the storage; 3: JOG: Jog. That is, after pressing this key, it will run according to the jog frequency and direction set by the program, and stop after releasing it; 4: RUN: Run key. If it is the panel control mode, press this key to start the inverter and enter the running state; 5: STOP: stop key. In case of panel control mode, press this key to stop the inverter. 6: Up arrow. This key can increase the running frequency or increase the parameter setting value. 7: Down arrow. This key can reduce the running frequency or reduce the parameter setting value. 8: SHIFT. shift key. This key is similar to the cursor in the OFFICE software. When the key is moved to the corresponding position, you can press the up and down arrows to modify the value at the pos

ZJSHUYI The role of automatic transfer switch.www.shuyitop.com; #automat...

图片
In the two-way power supply system, the automatic transfer switch switches the load circuit from the common power supply to the other (backup) power supply when one power supply has a power quality failure, so as to ensure the continuous, safe and reliable operation of the important load, and make the common power supply, The backup power supply and dual-circuit power supply system have the functions of voltage detection, automatic switching, automatic switching and automatic recovery, automatic starting and stopping of generators, etc. It is used in important occasions such as working conditions, hospitals, military sites, airports, communication facilities, computer centers, power plants, etc., to ensure the continuity of power supply. Web: www.shuyitop.com; Tel/Fax: 0086-577-62840011 Wechat/WhatsApp: 008613355775769 #ZJSHUYI #Chinashuyi #shuyitop #breakers #swtiches #Dualpowertransferswitch #Dualpower

ZJSHUYI What does a soft start consist of? Function? www.shuyitop.com; #...

图片
Soft starter is a novel motor control device that integrates motor soft start, soft stop, light load energy saving and various protection functions. The main composition is a three-phase parallel thyristor and its electronic control circuit connected in series between the power supply and the controlled motor. Different methods can be used to control the conduction angle of the three-phase parallel thyristor, so that the input voltage of the controlled motor changes according to different requirements, and different functions can be realized. The soft starter changes the starting characteristics of the motor by changing the output voltage and boost time. The soft starter uses a three-phase parallel thyristor as a voltage regulator, which is connected between the power supply and the motor stator. Such a circuit is like a three-phase fully-controlled bridge rectifier circuit. When the soft starter is used to start the motor, the output voltage of the thyristor gradually increases, and

ZJSHUYI The function of the relay base is as follows. www.shuyitop.com; ...

图片
The function of the relay base is as follows: (1) Current relay: reflects the increase of current and acts as the starting element and measuring element of current protection. (2) Voltage relay: It acts to reflect the change of voltage (over or under). (3) Time relay: As a time element, it is used to establish the necessary action delay. (4) Intermediate relay: its function is to: increase the number of contacts to control different circuits; increase the contact capacity to disconnect or connect circuits with larger currents; provide the necessary delay to meet protection and automatic devices requirements. (5) Signal relay: used as action indicator in protection and automatic devices. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #ZJSHUYI #Chinashuyi #shuyitop #relay #relaybase

ZJSHUYI What is a temperature controller.www.shuyitop.com; #temperaturec...

图片
Thermostat refers to a series of automatic control elements that undergo physical deformation inside the switch according to the temperature change of the working environment, thereby producing some special effects and generating on or off actions, also called temperature control switches and temperature protectors. , temperature controller, referred to as temperature controller. Or the temperature is transmitted to the temperature controller through the temperature protector, and the temperature controller issues a switch command to control the operation of the equipment to achieve the ideal temperature and energy saving effect. Thermostats have a very wide range of applications, and are used in many products such as home appliances, motors, refrigeration or heating according to different types of thermostats. The working principle is to automatically sample and monitor the ambient temperature through the temperature sensor. When the ambient temperature is higher than the control set

ZJSHUYI The necessity of connecting soft starter to bypass contactor. ww...

图片
The contactor connected in parallel with the soft starter is called a bypass contactor, because the long-term use of the soft starter to start will cause a lot of pressure on the thyristor. Excessive current of the thyristor for a long time is not good for it. At the same time, it is also easy to cause problems by relying on the circuit board to trigger the thyristor. It is better to use a traditional contactor to maintain it, because the soft start is only useful during the motor starting process and runs at the power frequency. It is the same as the usage of ordinary motors, so it is still reliable to use traditional contactors. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #softstarter #motorsoftstar #softstarters #softstartechnology #softstartermarket #softstarterprice #BypassContactor #BypassContactorSoftStart #ZJSHUYI #chinashuyi #shuyitop

ZJSHUYI What is the function of the soft starter configuration bypass co...

图片
There are two types of soft starters, one does not need an external contactor and runs directly after starting, and the other is a built-in bypass contactor. The contactor connected in parallel on the soft starter is called a bypass contactor, because the long-term use of the soft starter to start will cause a lot of pressure on the thyristor. If the thyristor is in an excessive current for a long time, and the thyristor is triggered by the circuit board at the same time, it will be prone to failure problems. It can be maintained with a traditional contactor, because the soft start is only useful in the process of starting the motor, and it is the same as that of a common motor during power frequency operation, so it is more reliable to use a traditional contactor. The soft starter is a device that can reduce the starting current of the AC motor when starting. When the motor completes the starting process, the device can start the bypass contactor according to the set time, thereby

ZJSHUYI How to choose the inverter.www.shuyitop.com; #frequencyconverter

图片
First of all, when selecting an inverter, the power of the motor should be the basic principle. The rated capacity of the inverter is generally marked with KW and current. Under normal circumstances, when selecting an inverter, the corresponding three-phase general-purpose inverter is selected based on the rated KW of the motor. For example: fans, pumps and other equipment. Generally, when selecting a motor of grade 6 or above, it needs to be properly enlarged. The load needs to be controlled by a motor with a reducer, and the power of the inverter needs to be appropriately amplified. For example: cranes, coal mine winches and other equipment. The selection of the inverter should also be based on the load characteristics. If it is applied to frequent startup, the instantaneous current fluctuates greatly, or the load is heavy, the inverter with one or two gears larger can be selected. For example: sand making machine, ball mill and other equipment. When the occasion used for control is