ZJSHUYI The phenomenon of inverter overcurrent.www.shuyitop.com; #freque...

The phenomenon of inverter overcurrent (1) When restarting, it trips as soon as the speed increases, which is a very serious phenomenon of overcurrent. The main reasons are: the load is short-circuited, the mechanical parts are stuck; the inverter module is damaged; the torque of the motor is too small, etc. (2) It jumps when it is powered on. This phenomenon generally cannot be reset. The main reasons are: the module is broken, the drive circuit is broken, and the current detection circuit is broken. (3) When restarting, it does not trip immediately but during acceleration. The main reasons are: the acceleration time setting is too short, the current upper limit setting is too small, and the torque compensation (V/F) setting is high. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #VFD #INVERTER #frequencyinverter #frequencyconverter

评论

此博客中的热门博文

ZJSHUYI Do you know what is a fire control cabinet? www.shuyitop.com; #S...

ZJSHUYI Common problems of soft starters. www.shuyitop.com; #softstarte...

ZJSHUYI ZJSHUYI Difference between soft starter and frequency converter....