ZJSHUYI The reason for the total burnout of the inverter with the motor....

1. When the motor current in the inverter is set too large, the motor protection parameter is set too large, and the inverter cannot protect the motor according to the actual current of the motor when the motor is overloaded, which will cause the motor to overload, heat, or burn. 2. When the motor speed is not set correctly, if the set speed exceeds the rated speed of the motor, the motor will run in the constant power area at a higher speed at the rated frequency point. The higher the speed, the smaller the output torque, which will cause the motor Excessive current overheats or burns the motor. 3. If the acceleration and deceleration time of the motor is too short, the inverter will report an overcurrent fault for protection. 4. The inverter adopts vector control, but the motor and the inverter do not have paired self-learning, which causes the parameters of the inverter to control the motor to be inconsistent with the actual value of the motor, causing the control accuracy to deteriorate, and the motor to heat or burn. www.shuyitop.com; Tel/Fax: 0086-577-62840011 WhatsApp: 008613355775769 #VFD #INVERTER #frequencyinverter #frequencyconverter #Chinashuyi #converter #inverters #vfds #vfdmarket #ZJSHUYI #SHUYITOP

评论

此博客中的热门博文

ZJSHUYI Do you know what is a fire control cabinet? www.shuyitop.com; #S...

ZJSHUYI Common problems of soft starters. www.shuyitop.com; #softstarte...

ZJSHUYI ZJSHUYI Difference between soft starter and frequency converter....